Technical appendix

Recommended installation bores for screwed cable glands (PG and metric)
PG Thread Required installation bore mm Metric Required installation bore mm
Thread ø mm Through hole Core hole Thread Through hole Core hole
Pg 7 12.5 13 11.5 M 12 x 1.5 12.5 10.5
Pg 9 15.2 15.7 14 M 16 x 1.5 16.5 14.5
Pg 11 18.6 19 17.4 M 20 x 1.5 20.5 18.5
Pg 13.5 20.4 21 19 M 25 x 1.5 25.5 23.5
Pg 16 22.5 23 21.25 M 32 x 1.5 32.5 30.5
Pg 21 28.3 28.8 27 M 40 x 1,5 40.5 38.5
Pg 29 37.0 37.5 35.5 M 50 x 1.5 50.5 48.5
Pg 36 47.0 47.5 45.5 M 63 x 1.5 63.5 61.5
Pg 42 54.0 54.5 52.5
Pg 48 59.0 59.8 58

Working guide values with good lubrication
Recommended revolutions per min. (rpm). For bore diameters not specified, select corresponding speed. Cutting performance and d urability are significantly increased by good
lubrication (CIMCO boring lubricant no. 20 1307) and by abiding by the recommended speeds.

Step drill
ø PG Alloyed Unalloyed Non-ferrous Plastic
mm dimension steel steel metals plywood
12.5 7 360 650 1200 2900
15.2 9 300 540 960 2400
18.6 11 250 450 800 2000
20.4 13.5 230 400 720 1800
22.5 16 200 370 650 1650
28.3 21 165 300 520 1300
37.0 29 125 215 400 1000

CIMCO order no.
Diamand core drill 20 7380 ff 112 no X X X X X XXXXXX
Hammer drill 20 7311 ff 104 yes X X X X X X X
T.C.T. hole saw 20 7714 ff 112 no X X X X X X X X
HSS bi-metal hole saw 20 7414 ff 110 no X X X X X
Step drill 20 1200 ff 104 no X X X X X X X X
Sheet taper drill 20 1280 ff 105 no X X X X X X X X
Twist drill 20 0314 ff 100 no X X X X X X X X
Stone and concrete drill 20 1600 ff 101 yes X X XXXXX
Hammer drill 20 8100 ff 103 yes X X X X X X
Multi-purpose drill 20 1880 ff 103 no X X XXXXXXXXX
Cased drill 20 6306 ff 90 no X XXXX

Catalogue p.
With hammer
Standard
Hex
SDS
Granite
Concrete
Armoured concrete
Clinker brick
Masonry
e.g. lime sand brick
Tiles
Marble
Natural stone
Artificial stone e.g.
aerated concrete
Hard wood
Soft wood
Plastic
Drywall
e.g. Rigips
Aluminium
Other non-ferrous
metals
Steel sheets
VA steel sheets

Receptacle Material

Keyword: new dimensions in electrical installation.
The European standard DIN EN 50262 “Cable Glands for Electrical
Installations” has been valid since 1 January 2000 thus abolishing the PG system
common in Germany. Electrical installation tubes, screwed cable glands,
sockets, housings and cabinets are affected.
The change provides advantages to the user:

-10 PG sizes are replaced with 8 metric sizes
- With each metric size a sealing area is achieved that is approx. 20% larger
than with the PG size
- The outer thread diameter can be derived directly from the type
designation (example: M16 = 16 mm outer diameter)
During the transition period, both systems are available simultaneously (for
replacement and repair installations). CIMCO recommends having both
types of step drills, thread cutters and screw punchers on hand.

Sheet taper drill
ø Alloyed Unalloyed Non-ferrous Plastic
mm steel steel metals plywood
3-14 600-400 800-500 2000-1500 3000-2000
6-20 500-200 700-400 1800-1000 2500-1500
16-30 200-100 400-200 1000- 500 1500-1000
25-40 100- 80 300-150 500- 300 1000- 500
36-52 80- 50 200-100 300- 200 600- 200

Advice and ordering: Phone: +49 (0)2191 3718 01, Fax: +49 (0)2191 3718 85, E-mail: info@cimco.de